Model |
LRS-100-5 |
LRS-100-12 |
LRS-100-15 |
LRS-100-24 |
LRS-100-36 |
LRS-100-48 |
|
output |
DC voltage |
5V |
12V |
15V |
24V |
36V |
48V |
Rated current |
18A |
8.5A |
7A |
4.5A |
2.8A |
2.3A |
|
Current range |
0~18A |
0~8.5A |
0~7A |
0~4.5A |
0~2.8A |
0~2.3A |
|
Rated power |
90W |
102W |
105W |
108W |
100.8W |
110.4W |
|
Ripple&noise |
100mVp-p |
120mVp-p |
120mVp-p |
150mVp-p |
200mVp-p |
200mVp-p |
|
DC voltage ADJ. range |
±10% |
±10% |
±10% |
±10% |
±10% |
±10% |
|
Voltage tolerance Note.3 |
±3% |
±2% |
±1% |
±1% |
±1% |
±1% |
|
Line regulation Note.4 |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Load regulation Note.5 |
±2% |
±1% |
±0.5% |
±0.5% |
±0.5% |
±0.5% |
|
Setup,rise,hold up time |
800ms,30ms,55ms/230VAC(full load) |
||||||
input |
Voltage range |
90~264VAC,127~373VDC |
|||||
Frequency range |
47~63HZ |
||||||
AC current |
1.9A/115VAC 1.2A/230VAC |
||||||
Inrush current |
Cold start 50A/230VAC |
||||||
Efficiency |
86% |
88% |
88.5% |
90% |
90.5% |
91% |
|
Leakage current |
<0.75mA/240VAC |
||||||
protection |
overload |
Rated output power110%~150% start over load protection |
|||||
protection type:hiccup mode,auto-recovery after fault condition is removed |
|||||||
Over voltage |
Rated output voltage 115%~135% Start over voltage protection |
||||||
Protection type:hiccup mode,auto-recovery after fault condition is removed |
|||||||
environment |
Working temp,humidity |
-30ºC~+70ºC(Please refer to"derating curve") |
|||||
Storage temp,humidity |
-40ºC~+85ºC,10%~95%RH non-condensing |
||||||
Withstand vibration |
10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes |
||||||
safety |
Withstand voltage |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
|||||
Isolation resistance |
I/P-O/P,I/P-FG,O/P-FG:100M ohms/500VDC |
||||||
Fit standard |
Safety standards |
Compliance to UL60950-1,TUV EN60950-1,GB4943 |
|||||
EMC emission |
Compliance to EN55022(CISPR22)Class A,GB9254 Class B,EN55014,EN61000-3-2,3 |
||||||
EMC immunity |
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024,EN61000-6-1 |
||||||
others |
Dimension |
129*97*30mm(L*W*H) |
|||||
Weight/packing |
0.34kg/40pcs/14.6kg/0.025m³/0.88CUFT |
||||||
MTBF |
≥705K hrs min. MIL-HDBK-217F(25ºC) |
||||||
note |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4.Line regulation is measured from low line to high line at rated load. 5.Load regulation is measured from 0% to 100% rated load 6.The ambient temperature derating of 5ºC/1000 m is needed for operating altitude greater than 2000m(6500ft) 7.The power supply is considered as a component which will be installed into a finalequipment.The final equipment must be re-confirmed that it still meets EMC directives.For guidance on how to perform these EMC tests. |