Features:
1.SVC current vector control mode, V/F control mode is optional;
2.V/F curve multi-node setting, flexible configuration;
3.Multi-function programmable input port, programmable relay output;
4.Over-current, over-voltage, overload and other monitoring protection, maximize the
protection of customer equipment and inverter;
5.Unique adaptive control technology, unique pulse width modulation technology, in
order to optimize the control performance;
6.Compact structure design, small volume, reliable performance.
| Model Table |
| Input Voltage | Rated Power (KW) | Rated Input Current (A) | Rated Output Current (A) | Adapted Motor (KW) |
| Single phase 220V | 0.75KW | 8.2 | 4 | 0.75KW |
| 1.5KW | 14 | 7 | 1.5KW | |
| 2.2KW | 23 | 9.6 | 2.2KW | |
| Three-phase 380V | 0.75KW | 3.4 | 2.1 | 0.75KW |
| 1.5KW | 5 | 3.8 | 1.5KW | |
| 2.2KW | 5.8 | 5.1 | 2.2KW | |
| 4KW | 10.5 | 9 | 4KW | |
| 5.5KW | 14.6 | 13 |
5.5KW |
| Product Parameters |
| Input voltage |
Single phase 220V;Three phase 380V |
| Input frequency | 50Hz/60Hz, fluctuation less than 5% |
| Output voltage | 3 phases: 0 ~ input voltage |
| General application | 150% rated current for 60S |
| Light load application | 120% rated current 180S |
| Control method |
V/f control, sensorless magnetic flux vector control (SVC) without PG card Operating mode: speed control |
| Speed range | 1:100 (voltage/frequency), 1:200 (SVC) |
| Speed regulation accuracy | ±0.5% (V/f), ±0.2% (SVC), ±0.02% (VC) |
| Speed response | 5Hz (voltage/frequency), 20Hz (passive voltage control), 50Hz(AC) |
| Frequency range | 0.00~ 600.00Hz (voltage/frequency), 0.00~ 200.00Hz (passive vector control), 0.00~ 400.00Hz (VC digital setting: 0.01Hz, analog setting: maximum frequency× 0.1% |
| Starting torque | 150%/0.5Hz (voltage/frequency), 180%/0.25Hz (passivevoltage control), 200%/0Hz (voltage) |
| SVC | 10% within 5Hz, 5% above 5Hz, vc: 3.0% |
| Product Advantages |
|
01. V/F control, vector control, output torque control |