MODEL | MDR-40-5 | MDR-40-12 | MDR-40-24 | MDR-40-48 | |
OUTPUT |
DC VOLTAGE | 5V | 12V | 24V | 48V |
RATED CURRENT | 6A | 3.3A | 1.67A | 0.83A | |
CURRENT RANGE | 0~6A | 0-3.3A | 0 ~ 1.67A | 0 ~ 0.83A | |
RATED POWER | 30W | 40W | 40W | 40W | |
RIPPLE & NOISE (max.) Note.2 | 80mVp-p | 120mVp-p | 150mVp-p | 200mVp-p | |
VOLTAGE ADJ. RANGE | 5-6V | 12 ~ 15V | 24 - 30V | 48 - 56V | |
VOLTAGE TOLERANCE Note.3 | ±2.0% | ±1.0% | ±1.0% | ±1.0% | |
LINE REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
LOAD REGULATION | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
SETUP, RISE TIME Note.5 | 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load | ||||
HOLD UP TIME (Typ.) | 50ms/230VAC 20ms/115VAC at full load | ||||
INPUT |
VOLTAGE RANGE | 85 ~ 264VAC 120-370VDC | |||
FREQUENCY RANGE | 47~63Hz | ||||
EFFICIENCY (Typ.) | 78% | 86% | 88% | 88% | |
AC CURRENT (Typ.) | 1.1 A/115 VAC 0.7A/230VAC | ||||
INRUSH CURRENT (Typ.) | COLD START 30A/115VAC,60A/230VAC | ||||
LEAKAGE CURRENT | <1mA/240VAC | ||||
PROTECTION |
OVERLOAD | 105 ~ 150% rated output power | |||
Protection type: Constant current limiting, recovers automatically after fault condition is removed | |||||
OVERVOLTAGE | 6.25 - 7.25V | 15.6 -18V | 31.2-36V | 57.6-64.8V | |
Protection type : Shut down o/p voltage, re-power on to recover | |||||
FUNCTION | DC OK SIGNAL | Relay contact rating{max.): 30V/1A resistive | |||
ENVIRONMENT |
WORKING TEMP. | -20 ~ +70"C (Refer to "Derating Curve") | |||
WORKING HUMIDITY | 20 - 90% RH non-condensing | ||||
STORAGE TEMP, HUMIDITY | -40 ~ +85°C, 10 ~ 95% RH | ||||
TEMP. COEFFICIENT | ±0.03%/°C (0 ~50°C) | ||||
VIBRATION | Component: 10 - 500Hz, 2G 10min./1 cycle, period for60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 | ||||
SAFETY & EMC (Note 4) |
SAFETY STANDARDS | UL508, UL60950-1, TUV EN60950-1 approved | |||
WITHSTAND VOLTAGE | l/P-0/P:3KVAC l/P-FG:2KVAC 0/P-FG:0.5KVAC | ||||
ISOLATION RESISTANCE | l/P-O/P, l/P-FG, 0/P-FG:>100M Ohms/500VDC/25°C/70% RH | ||||
EMC EMISSION | Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3 | ||||
EMC IMMUNITY | Compliance to EN61000-4-2, 3,4, 5, 6,8,11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A | ||||
OTHERS |
MTBF | 301.7K hrs min. MIL-HDBK-217F (25°C) | |||
DIMENSION | 40*90*100mm (W*H*D) | ||||
PACKING | 0.3Kg; 40pcs/17Kg/0.82CUFT | ||||
NOTE | 1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. 3.Tolerance : includes set up tolerance, line regulation and load regulation. 4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." 5.Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. |