Model | SMV-10-12 | SMV-10-15 | SMV-10-24 | |
Output | DC output Voltage | 12V | 15V | 24V |
Voltage tolerance | ±1.0% | ±1.0% | ±1.0% | |
Rated Current | 0.85A | 0.67A | 0.42A | |
Related Power | 10w | 10w | 10w | |
Wave&Noise | 50mVp-p | 50mVp-p | 50mVp-p | |
Set up,rise,hold up time | 200ms 100ms 30ms | |||
Input | Voltage Range | 170-264VAC 47-63HZ | ||
Input Current | 0.3A/230VAC | |||
Efficiency | 75% | 80% | 85% | |
AC inrush current | Cold start current 30A /230VAC | |||
Leakage current | <0.5mA/240VAC | |||
Protection | Overload | Related output power 105-135% start overload protection | ||
Protection type: hiccup mode, recovery after restart power | ||||
Over voltage | Reted output power 135-150% start over voltage protection | |||
Protection type: hiccup mode, recovery after restart power | ||||
Over temperature | When temp of transistor inner is over 150, start over temp protection | |||
pretect mode:cutoff output,auto-recover after temperature become normal | ||||
Environment | Working temp humidity | -10~+60°C 20%~90%RH | ||
Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | |||
Withstand vibration | 10-500Hz,2G 10min/Ccle, period for 60min, each axes | |||
Safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVA O/P-FG:0.5KVA | ||
Isolation resistance | I/P-O/P: I/P-FG,O/P-FG:100M Ohms/500VDC | |||
Standard | Safety standard | Fit UL1012 IP67 | ||
EMC standard | Fit EN55022 CLASSA | |||
Size | size | L135*W28*H20mm | ||
Package | 0.16kg, 100 pcs/16kg | |||
Note:1.All parameters not specially mentioned are measured at 230VAC input, related load and 25 f ambient temperature.2.Wave&noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.3.Tolerance: includes set up tolerance, line regulation and load regulation. |