MODEL |
MDR-60-5 |
MDR-60-12 |
MDR-60-24 |
MDR-60-48 |
OUTPUT |
DC VOLTAGE |
5V |
12V |
24V |
48V |
RATED CURRENT |
10A |
5A |
2.5A |
1.25A |
CURRENT RANGE |
0 ~ 10A |
0 ~5A |
0 -2.5A |
0-1.25A |
RATED POWER |
50W |
60W |
60W |
60W |
RIPPLE & NOISE (max.) |
80mVp-p |
120mVp-p |
150mVp-p |
200mVp-p |
VOLTAGE ADJ. RANGE |
5 -6V |
12-15V |
24 - 30V |
48 ~ 56V |
VOLTAGE TOLERANCE |
±2.0% |
±1.0% |
±1.0% |
±1.0% |
LINE REGULATION |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
LOAD REGULATION |
±1.5% |
±1.0% |
±1.0% |
±1.0% |
SETUP, RISE TIME Note.5 |
500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load |
HOLD UP TIME (Typ.) |
50ms/230VAC 20ms/115VAC at full load |
INPUT |
VOLTAGE RANGE |
85 - 264VAC 120-370VDC |
FREQUENCY RANGE |
47 ~ 63Hz |
EFFICIENCY (Typ.) |
78% |
86% |
88% |
87% |
AC CURRENT (Typ.) |
1.8A/115VAC 1A/230VAC |
INRUSH CURRENT (Typ.) |
COLD START 30A/115VAC,60A/230VAC |
LEAKAGE CURRENT |
<1mA/240VAC |
PROTECTION |
OVERLOAD |
105 - 150% rated output power |
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
OVERVOLTAGE |
6.25-7.25V |
15.6 - 18V |
31.2-36V |
57.6 - 64.8V |
Protection type: Shut down o/p voltage, re-power on to recover |
FUNCTION |
DC OK SIGNAL |
Relay contact rating (max.): 30V/1A resistive |
ENVIRONMENT |
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY |
-40 ~ +85°C, 10 ~ 95% RH |
TEMP. COEFFICIENT |
±0.03%/°C (0 - 50°C) |
VIBRATION |
Component: 10 - 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6 |
SAFETY &EMC |
SAFETY STANDARDS |
UL508, UL60950-1, TUV EN60950-1 approved |
WITHSTAND VOLTAGE |
l/P-0/P:3KVAC l/P-FG:2KVAC 0/P-FG:0.5KVAC |
ISOLATION RESISTANCE |
l/P-O/P, l/P-FG, 0/P-FG:>100M Ohms/500VDC/25°C/70% RH |
EMC EMISSION |
Compliance to EN55011, EN55022 (CISPR22), EN61204-3 Class B, EN61000-3-2,-3 |
EMC IMMUNITY |
Compliance to EN6100(M-2,3,4,5,6,8,11, EN55024, EN61000-6-2, EN61204-3, heavy industry level, criteria A |
OTHERS |
MTBF |
299.2K hrs min. MIL-HDBK-217F (25°C) |
DIMENSION |
40*90*100mm (W*H*D) |
PACKING |
0.33Kg; 60pcs/20Kg/0.82CUFT |
NOTE |
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature. |
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 47uf parallel capacitor. |
3. Tolerance : includes set up tolerance, line regulation and load regulation. |
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies. |
5. 5.Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time. |