Customization: | Available |
---|---|
Output Type: | Triple |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 8/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | T-30A | T-30B | |||||
Output | DC Voltage | Ch1:5v | Ch2:12v | Ch1:5v | Ch2:5v | Ch1:12v | Ch2:12v |
Voltage tolerance | ±2.0% | ±6.0% | ±6.0% | ±2.0% | ±6.0% | ±6.0% | |
Rated Current | 0.5-8A | 0.2-1A | 0-1A | 0.5-3A | 0.2-1A | 0-0.5A | |
Related Power | 30w | 30w | |||||
Wave&Noise | 80mVp-p | 120mVp-p | 80mVp-p | 150mVp-p | 120mVp-p | 150mVp-p | |
DC Voltage ADJ range | Ch1:-9%~+10% | ||||||
Set up,rise,hold up time | 200ms 100ms 30ms | ||||||
Input | Voltage Range | 95 ~132VAC 180-264VAC 47-63HZ 120-370VDC | |||||
AC Current | 1.6A/115VAC 0.8A/230VAC | ||||||
Efficiency | 72% | 72% | |||||
AC inrush current | Cold start current 18A/115V 36A /230VAC | ||||||
Leakage current | <3.5mA/240VAC | ||||||
Protection | Overload | Related output power 105-150% start overload protection | |||||
Protection type: cutoff output, recovery after restart power | |||||||
Over voltage | Ch2 :115%~135% | ||||||
Hiccup mode,recovers automatically after fault condition | |||||||
Environment | Working temp humidity | -10~+60°C 20%~90%RH | |||||
Storage temp, humidity | -20~+85°C 20%~90%RH Non-condensing | ||||||
Withstand vibration | 10-500Hz,2G 10min/1 cycle, period for 60min, each axes | ||||||
Safety | Withstand voltage | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | |||||
Isolation resistance | I/P-O/P:I/P-FG:O/P-FG: 100M Ohms/500VDC | ||||||
Standard | Safety standard | Fit UL1012 | |||||
Refer | Design refer to GB4943,UL60950,EN60950 | ||||||
EMC standard | Design refer to GB9254,EN55022 Class A | ||||||
Size | size | L129*W98*H38mm | |||||
Package | 0.42kg, 45pcs/19kg | ||||||
Note:1.All parameters not specially mentioned are measured at 230VAC input, related load and 25 degree of ambient temperature. | |||||||
2.Wave&noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor. | |||||||
3.Tolerance: includes set up tolerance, line regulation and load regulation. |