Customization: | Available |
---|---|
Output Type: | Single |
Warranty: | 2 Years |
Still deciding? Get samples of US$ 8.7/Piece
Request Sample
|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model |
AS-100-5 | AS-100-12 | AS-100-15 | AS-100-24 | AS-100-48 | |
Output | DC output Voltage | 5V | 12V | 15V | 24V | 48V |
Voltage tolerance | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
Rated Current | 20A | 8.5A | 6.7A | 4.5A | 2A | |
Related Power | 100w | 100w | 100w | 100w | 100w | |
Wave&Noise | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | 100mVp-p | |
Adjustable range for DC Voltage | ±10% | ±10% | ±10% | ±10% | ±10% | |
Set up,rise,hold up time | 200ms 100ms 20ms | |||||
Input | Voltage Range | 85 ~132VAC 170-264VAC 47-63HZ 240-370VDC | ||||
Input Current | 1.6A/115VAC 0.8A/230VAC | |||||
Efficiency | 81% | 81% | 84% | 84%% | 84% | |
AC inrush current | Cold start current 15A/115V 30A /230VAC | |||||
Leakage current | <0.5mA/240VAC | |||||
Protection | Overload | Related output power 105-150% start overload protection | ||||
Protection type: cutoff output, recovery after restart power | ||||||
Over voltage | 5.75V-6.75V | 13.8V-16.2V | 17.2V-20.2V | 27.6V-32.4V | 55V-64.8V | |
Hiccup mode,recovers automatically after fault condition | ||||||
Environment | Working temp humidity | -10~+60°C 20%~90%RH | ||||
Stor temp, humidity | -20~+85°C 20%~90%RH Non-condensing | |||||
Safety | Withstand voltage | I/P-O/P:1.5KVAC 1min | ||||
I/P-FG:1.5KVAC 1min | ||||||
O/P-FG:0.5KVAC 1min | ||||||
Standard | Safety standard | Fit UL1012 | ||||
Refer | Design refer to GB4943,UL60950,EN60950 | |||||
EMC standard | Design refer to GB9254,EN55022 Class A | |||||
Size | size | L159*W98*H38mm | ||||
Package | 0.45kg, 30pcs/14kg | |||||
Note:1.All parameters not specially mentioned are measured at 230VAC input, related load and 25 degree of ambient temperature.2.Wave&noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf&47uf parallel capacitor.3.Tolerance: includes set up tolerance, line regulation and load regulation. |