| Model | RSP-3000-24 | RSP-3000-36 | RSP-3000-48 | RSP-3000-60 | RSP-3000-72 | RSP-3000-110 | |
| Output | DC voltage | 24V | 36V | 48V | 60V | 72V | 110V |
| AC220V In Rated current | 125A | 83.3A | 62.5A | 50A | 41.6A | 27.2A | |
| AC220V In Rated power | 3000W | 3000W | 3000W | 3000W | 3000W | 3000W | |
| AC220V In Efficiency | 89% | 91.20% | 91.60% | 92% | 92.30% | 93.40% | |
| AC110V In Rated current | 91.7A | 61.1A | 45.8A | 36.7A | 30.6A | 22.7A | |
| AC110V In Rated power | 2200W | 2200W | 2200W | 2200W | 2200W | 2200W | |
| AC110V In Efficiency | 87% | 88.50% | 89.50% | 90% | 90.60% | 91.30% | |
| Ripple&noise | 160mVp-p | 180mVp-p | 200mVp-p | 200mVp-p | 230mVp-p | 300mVp-p | |
| Voltage adj.range | 17-25V | 25-36.5V | 33-48.5V | 41-61V | 50-73V | 74-110V | |
| Voltage tolerance | ±3.0% | ±3.0% | ±3.0% | ±3.0% | ±3.0% | ±3.0% | |
| Line regulation | ±0.3% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | ±0.5% | |
| Load regulation | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | ±1.0% | |
| Set up,rise time | 3s,60ms/220VAC 8s,60ms/110VAC(at full load) | ||||||
| Hold up time(Typ.) | 10ms(at full load) | ||||||
| Topology | PFC | Interlaced boost | |||||
| PWM | Interlaced parallel double tube forward excitation | ||||||
| Input | Voltage range | 100-264VAC 124~370VDC | |||||
| Frequency | 47 ~ 63Hz | ||||||
| Power factor | PF>0.97/220VAC PF>0.98/110VAC(at full load) | ||||||
| Standby Consumption | 10W | ||||||
| Inrush current | 33A/115V 60A/230V | ||||||
| Input connection | 3Pin KF78 type,pin=14mm,PCB fence type terminal with protective shell | ||||||
| Function | PS-ON | PS-ON Terminal short circuit:power off output voltage | |||||
| PS ON Open circuit of terminal:open the output voltage | |||||||
| Output voltage adj. | The output voltage can be adjusted, and the ADJV potentiometer can be manually adjusted, Range as per parameters listed in the above table. |
||||||
| Output current adj. | The output current is adjustable, and the ADJV potentiometer is manually adjusted. When the load reaches the current setting value, the power supply will output constant current |
||||||
| Auxliary voltage output | The machine provides an auxiliary voltage output of 12V-300mA | ||||||
| Protection | Over voltage | Cut off the output at 115% - 120% of the maximum output voltage, and it will not recover automatically. It will recover only after power off and restart |
|||||
| Short circuit | Short-term momentary short circuit: Power supply shuts down and automatically recovers after 3 seconds.Long-duration continuous short circuit: Power supply shuts down and attempts to restart every 3 seconds (hiccup mode). | ||||||
| Overload | 1. Protection Mode: Constant Current Limiting, where the output current value is locked and remains unchanged, while the output voltage decreases as the load increases. 2. When a load of approximately 2.5 times the rated power is applied, it exceeds the power supply's overload constant current limiting range, effectively resembling a short circuit. In this case, the power supply will shut down and attempt to restart every 3 seconds (operating in hiccup mode). |
||||||
| Over temperature | PWM transistor's heat sink reaches 85°C ±5%, shut off output voltage; It will automatically recover when the temperature drops down to 75°C ±5%. |
||||||
| Under-voltage | 1. When the input voltage falls below AC 178V, the output will automatically be limited (the output power will be reduced to 2200W). 2. When the input voltage drops below AC 98V, the output will automatically be limited (the output power will be reduced to 2000W). 3. When the input voltage is below AC 88V, the power supply will not turn on. |
||||||
| Fan failure | If either one of the two cooling fans fails to rotate or if no fan is detected, the power supply will not output any voltage and the device will not power on. |
||||||
| Function | Remote control | Power ON:open or 0-0.8VDC between RC+(pin 4)&RC-(pin 3) on CN100 | |||||
| Power OFF:4-10VDC between RC+(pin 4)&RC-(pin 3) on CN100 | |||||||
| Remote sense | Compensate voltage drop on the load wiring up to 0.3V | ||||||
| Fan Control | RTH2≥50ºC±10ºC Fan on;RTH≤40ºC±10ºC Fan off | ||||||
| Environment | Working temperature | -30ºC-45ºC Use at 100% full power, and load reduction is required for over temperature (please refer to "Derating Curve") |
|||||
| Working humidity | 20 ~ 90% RH non-condensing | ||||||
| Storage temp,humidity | -40~+85ºC,10%-95%RH,non-condensing | ||||||
| Altitude | Only for use under 2500m altitude | ||||||
| Withstand voltage | I/P-O/P:3.0KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||||
| Isolation resistance | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC/70%RH | ||||||
| EMC emission | EN55032 CISPR32 ClassA EN61000-3-2.ClassA ; EN61000-3-3. EN61000-4-2.3.4.5.6.11. | ||||||
| Leakage current | <2.5mA/230VAC | ||||||
| Others | Cooling | Built in fan for heat dissipation (temperature controlled automatic speed regulating fan, 2 fans (ball type)), internal blowing mode |
|||||
| Fan Noise | In an indoor environment of about 20-25 decibels, two fans rotate at full speed, and about 50 decibels are measured 50 cm away from the power supply |
||||||
| Installation | (Horizontal installation) Length spacing: 236mm, width spacing: 205mm (refer to the dimension drawing) Use the matching mounting bracket (with M3 screws) |
||||||
| Size | 294*185*65mm (L*W*H) | ||||||
| Packing | 3.3kg | ||||||
| Note | 1. All Parameters NOT specially mentioned are measured at 230VAC input,rated load and 25ºC of ambition temperature. 2. Ripple & noise are measured at 20MHZ of bandwidth by using a 12'' twised pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance:includes set up tolerance ,line regulation and load regulation 4. Derating output is required under low input voltage. Please refer to the Derating Curve for details. 5. The power supply shall be confirmed with the terminal equipment for electromagnetic compatibility. 6. The ambient temperature decreases at a rate of 5 degrees Celsius per 1000 meters elevation when the altitude exceeds 2000 meters. |
||||||



| MODEL | RSP-3000-12 | RSP-3000-24 | RSP-3000-48 | |
| OUTPUT | DC VOLTAGE | 12V | 24V | 48V |
| OUTPUT | RATED CURRENT | 200A | 125A | 62.5A |
| OUTPUT | CURRENT RANGE | 0 ~ 200A | 0 ~ 125A | 0 ~ 62.5A |
| OUTPUT | RATED POWER | 2400W | 3000W | 3000W |
| OUTPUT | RIPPLE & NOISE (max.) Note.2 | 150mVp-p | 150mVp-p | 200mVp-p |
| OUTPUT | VOLTAGE ADJ. RANGE | 10.8 ~ 13.2V | 22 ~ 28V | 43 ~ 56V |
| OUTPUT | VOLTAGE TOLERANCE Note.3 | ±1.0% | ±1.0% | ±1.0% |
| OUTPUT | LINE REGULATION | ±0.5% | ±0.5% | ±0.5% |
| OUTPUT | LOAD REGULATION | ±0.5% | ±0.5% | ±0.5% |
| OUTPUT | SETUP, RISE TIME | 1000ms, 80ms at full load | ||
| OUTPUT | HOLD UP TIME (Typ.) | 10ms at full load | ||
| INPUT | VOLTAGE RANGE | 110~ 264VAC 254 ~ 370VDC | ||
| INPUT | FREQUENCY RANGE | 47 ~ 63Hz | ||
| INPUT | POWER FACTOR (Typ.) | 0.95/230VAC at full load | ||
| INPUT | EFFICIENCY (Typ.) | 87.5% | 90% | 91.5% |
| INPUT | AC CURRENT (Typ.) | 20A/180VAC 16A/230VAC | ||
| INPUT | INRUSH CURRENT (Typ.) | 60A/230VAC | ||
| INPUT | LEAKAGE CURRENT | <2.0mA / 240VAC | ||
| PROTECTION | OVERLOAD | 100 ~ 112% rated output power | ||
| PROTECTION | OVERLOAD | User adjustable continuous constant current limiting or constant current limiting with delay shutdown after 5 seconds, re-power on to recover | ||
| PROTECTION | OVER VOLTAGE | 13.8 ~ 16.8V | 28.8 ~ 33.6V | 57.6 ~ 67.2V |
| PROTECTION | OVER VOLTAGE | Protection type : Shut down o/p voltage, re-power on to recover | ||
| PROTECTION | OVER TEMPERATURE | Shut down o/p voltage, recovers automatically after temperature goes down | ||
| FUNCTION | AUXILIARY POWER(AUX) | 12V 0.1A(Only for Remote ON/OFF control) | ||
| FUNCTION | REMOTE ON/OFF CONTROL | Please see the Function Manual | ||
| FUNCTION | ALARM SIGNAL OUTPUT | Please see the Function Manual | ||
| FUNCTION | OUTPUT VOLTAGE TRIM Note.5 | 2.4 ~ 13.2V | 4.8 ~ 28V | 9.6 ~ 56V |
| FUNCTION | CURRENT SHARING | Please see the Function Manual | ||
| ENVIRONMENT | WORKING TEMP. | -20 ~ +70ºC (Refer to "Derating Curve") | ||
| ENVIRONMENT | WORKING HUMIDITY | 20 ~ 90% RH non-condensing | ||
| ENVIRONMENT | STORAGE TEMP., HUMIDITY | -40 ~ +85ºC, 10 ~ 95% RH | ||
| ENVIRONMENT | TEMP. COEFFICIENT | ±0.05%/ºC (0 ~ 50ºC) | ||
| ENVIRONMENT | VIBRATION | 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes | ||
| SAFETY & EMC (Note 4) |
SAFETY STANDARDS | UL60950-1, TUV EN60950-1 approved | ||
| SAFETY & EMC (Note 4) |
WITHSTAND VOLTAGE | I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC | ||
| SAFETY & EMC (Note 4) |
ISOLATION RESISTANCE | I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25ºC/ 70% RH | ||
| SAFETY & EMC (Note 4) |
EMC EMISSION | Compliance to EN55022 (CISPR22) Conduction Class B, Radiation Class A ; EN61000-3-2,-3 | ||
| SAFETY & EMC (Note 4) |
EMC IMMUNITY | Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, light industry level, criteria A | ||
| OTHERS | MTBF | 104.5K hrs min. MIL-HDBK-217F (25ºC) | ||
| OTHERS | DIMENSION | 278*177.8*63.5mm (L*W*H) | ||
| OTHERS | PACKING | 4Kg; 4pcs/16Kg/1.89CUFT | ||
| NOTE | 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." 5. Can't use the PWM signal to control the output voltage. 6. PV(PIN3) and PS(PIN4) of CN1 or CN2 must be shorted if "Output Voltage TRIM" function is not used. Otherwise, the power supply unit will have no output. PV(PIN3) and PS(PIN4) of CN1 or CN2 must be disconnected if "Output Voltage TRIM" function is used. Otherwise, the internal electrical components may be damaged, and the power supply unit may thus be out of order. |
|||