Suppliers with verified business licenses
MODEL | DR-120-12 | DR-120-24 | DR-120-48 | ||
OUTPUT | DC VOLTAGE | 12V | 24V | 48V | |
RATED CURRENT | 10A | 5A | 2.5A | ||
RATED POWER | 120W | 120W | 120W | ||
RIPPLE&NOISE | 80mVp-p | 80mVp-p | 150mVp-p | ||
VOLTAGE ADJ.RANGE | 4.75-5.5V | 10.8-13.2V | 13.5-16.5V | ||
VOLTAGE TOLERANCE | ±2.0% | ±1.0% | ±1.0% | ||
LINE REGULATION | ±0.5% | ±0.5% | ±0.5% | ||
LOAD REGULATION | ±1.0% | ±0.5% | ±0.5% | ||
SETUP,RISE TIME | 100ms,30ms/230VAC 100ms,30ms/115VAC at full load | ||||
HOLD UP TIME(TYP.) | 90ms/230VAC 12ms/115VAC at full load | ||||
INPUT | VOLTAGE RANGE | 85-264VAC 120-370VDC | |||
FREQUENCY RANGE | 47-63HZ | ||||
EFFICIENCY(Typ.) | 80% | 84% | 85% | ||
AC CURRENT(Typ.) | 4.5A/115VAC 0.5A/230VAC | ||||
INRUSH CURRENT | COLD START 30A/115VAC 60A/230VAC | ||||
PROTECTION | OVERLOAD | 105-150% RATED OUTPUT POWER | |||
Protection type:Hiccup mode,recovers automatically after fault condition | |||||
OVER VOLTAGE | 5.75V-6.75V | 13.8V-16.2V | 17.2V-20.25V | 27.6V-32.4V | |
Protection type:Hiccup mode,recovers automatically after fault condition | |||||
ENVIRONMENT | WORKING TEMP | -10~+60°C | |||
WORKING HUMIDITY | 20-90%RH non-condesing | ||||
STORAGE TEMP,HUMIDITY | -20~+85°C,10-95%RH | ||||
TEMP.COEFFICIENT | ±0.03%°C(0-50°C) | ||||
VIBRATION | 10-500HZ | ||||
SAFETY&EMC | SAFETY STANDARD | CE RoHS | |||
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC 1minute | ||||
ISOLATION RESISTANCE | I/P-O/P,I/P-FG,O/P-FG:100M Ohms/500VDC/25°C/70%RH | ||||
EMI CONDUCTION&RADIATION | Design refer to GB4943,UL60950,EN60950 | ||||
EMC STANDARD | Design refer to GB9254,EN55022 Class A | ||||
DIMENSION | L100*W65.5*H125.2mm | ||||
PACKING | 0.6kg,20pcs/13kg |