High Efficiency, High Reliability, Low Cost
AC Input Range:176~264Vac
100% Full Load Burn-In Test
Protections: Short Circuit / Over Load/Over Voltage/Over Temperature
LED Indicator For Power On
Cooling By Free Air Convection
Approvals: CE RoHS
2 Year Warranty
Dimensions: 295*145*155mm
Model |
|
S-1500-12 |
S-1500-15 |
S-1500-24 |
S-1500-48 |
Output |
DC output Voltage |
12V |
15V |
24V |
48V |
Voltage tolerance |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
Rated Current |
125A |
100A |
62A |
32A |
Related Power |
1500w |
1500w |
1500w |
1500w |
Wave&Noise |
240mVp-p |
240mVp-p |
240mVp-p |
300mVp-p |
Adjustable range for DC Voltage |
±10% |
±10% |
±10% |
±10% |
Set up,rise,hold up time |
1000ms 50ms 20ms |
Input |
Voltage Range |
170-264VAC 47-63HZ 120-370VDC |
Input Current |
8A/230VAC |
Efficiency |
83% |
84% |
85% |
87% |
AC inrush current |
Cold start current 50A /230VAC |
Leakage current |
<3.5mA/240VAC |
Protection |
Overload |
Related output power 105-150% start overload protection |
Protection type: cutoff output, recovery after restart power |
Over voltage |
13.8V-16.2V |
17.2V-20.2V |
27.6V-32.4V |
55V-64.8V |
Hiccup mode,recovers automatically after fault condition |
Environment |
Working temp humidity |
-10~+60°C 20%~90%RH |
Stor temp, humidity |
-20~+85°C 20%~90%RH Non-condensing |
Safety |
Withstand voltage |
I/P-O/P:1.5KVAC 1min |
I/P-FG:1.5KVAC 1min |
O/P-FG:0.5KVAC 1min |
Standard |
Safety standard |
Fit UL1012 |
Refer |
Design refer to GB4943,UL60950,EN60950 |
EMC standard |
Design refer to GB9254,EN55022 Class A |
Size |
size |
L295*W145*H155mm |
Package |
6.4kg, 4pcs/25kg |